Scope:
- Installation of approx. 1,700 m² of 150mm TRIMO Power T FTV panels and 1,550 m² of 172mm TRIMO Perform C systems forming fire-rated compartmentation and envelope areas
- Integration of 750 lm of 60-minute and 120-minute fire-rated linear seals across key interfaces and junctions
- Fire sealing of 44 service penetrations using passive fire protection systems
- Coordination of fire-rated systems across seven industrial units within the wider Radius Park development
Principal Contractor: Ventry Construction
Division: Firewall
Completion: August 2025
Value: £505,000.00